• Energy and Environment
  • Transport and Mobility

Laboratory of Electrotechnical Systems and Environment (LSEE)

Research unit - UR 4025

Description

The research conducted at the Laboratory of Electrotechnical Systems and Environment (LSEE, UR 4025) focuses on the environmental efficiency of rotating electrical machines and transformers. In other words, the laboratory researchers are designing more efficient electromagnetic components, constrained by their uses and accepted in their environment. A good example? An electric actuator on board an aircraft: it must be light, reliable and powerful!
Specifically, the members of the laboratory work on the design of efficient and silent electrical machines on the one hand and, on the other hand, on the structural reliability of electrical equipment with the detection of defects inherent in aging or the improvement of Electrical Insulation Systems (EIS). These two themes have a common focus: the design of machines capable of withstanding extreme internal temperatures.
A strong and historical identity of the LSEE focuses on the systematization of validation through experimentation. The test methods are well known and contribute to the attractiveness of the laboratory!

Contacts

  • Raphaël ROMARY

Informations

Rue Gérard Philippe
Université d'Artois, Faculté des Sciences Appliquées, Technoparc Futura
62400 BETHUNE

http://www.lsee.fr

Laboratory of Electrotechnical Systems and Environment

Expertises

Skills

• Electrical Machine Sizing
• Acoustic and vibration theoretical and experimental analyses
• Electrical Isolation System Testing of Electrical Machinery, Generators, Transformers and Connector Systems
• Measurement, characterization and modelling of electrostatic discharge phenomena in Electrical Insulation Systems (partial discharge, breakdown, etc.)
• Implementation of multi-stressed ageing campaign for the development of predictive models
• Diagnosis of aging of Electrical Insulation Systems
• Electrical and mechanical fault diagnosis
• Coil design without partial discharge
• High temperature electrical machine sizing
• Characterization of magnetic materials

Example(s) of projects

• Development of an Electrical Isolation System for an aeronautical actuator (HT° Motor Winding - 🡭)
• High temperature electrical insulation system for laminated Busbars (Varnishes insulated Laminated Busbar - 🡭)
• Solegel process wire emailing for high temperature applications (HI-Ecowire - 🡭)
• High temperature synchronous machine design (Accite - 🡭)
• Development of prototypes of high-performance electrical actuators (Intelligent Integrated Energy Converter - 🡭)

Example(s) of publications

• Roger, D., Vélu, G., Ait-Amar, S., & Babicz, S. (2020). High temperature machines: A comparison between ceramic-coated wires and anodized aluminum strips. International Journal of Applied Electromagnetics and Mechanics, 63(4), 715–724. 🡭
• Ichou, H., Roger, D., Rossi, M., Belgrand, T., & Lemaitre, R. (2020). Assessment of a grain oriented wound core transformer for solid state converter. Journal of Magnetism and Magnetic Materials, 504, 166658. 🡭
• Parent, G., Rossi, M., Duchesne, S., & Dular, P. (2019). Determination of Partial Discharge Inception Voltage and Location of Partial Discharges by Means of Paschen’s Theory and FEM. IEEE Transactions on Magnetics, 55(6), 1–4. 🡭
• Bauw, G., Cassoret, B., Romary, R., & Ninet, O. (2018). Damper winding for noise and vibration reduction of induction machine under sinusoidal conditions. International Journal of Applied Electromagnetics and Mechanics, 57(S1), 13–21. 🡭
• Cuevas, M., Romary, R., Lecointe, J.-P., Morganti, F., & Jacq, T. (2018). Noninvasive Detection of Winding Short-Circuit Faults in Salient Pole Synchronous Machine With Squirrel-Cage Damper. IEEE Transactions on Industry Applications, 54(6), 5988–5997. 🡭

All our publications can be found here

Collaborations/Partners/Scientific clients

International
• Applied and Computational Electromagnetics, Montefiore Institute, University of Liège, Belgique
• Ecole Nationale Polytechnique d'Alger, Algérie
• GRCAD (Grupo de Concepção e Análise de Dispositivos Eletromagnéticos), Universidade Federal de Santa Catarina, Campus Florianópolis, Bresil
• IMSI, Université Polytechnique de Lodz, Pologne
• Laboratoire des Systèmes Electriques et Télécommunications (LSET), Université Cadi Ayaad - Marrakech, Maroc

Collaborations/Partners/Private Clients

EOMYS, Thyssenkrupp, Electrical Steel, Flipo Richir, Auxel, Green Isoligth International (GII), Safran, Jeumont Electric, Ernéo, Securelec Socem, EREM, Optimex, TechMI, Mitsubishi Electric R&D, Bernard & Bonnefond, IFPEN, CRITTM2A (Joint laboratory in partnership)

Services offers

Applications sectors

  • Science / Research

Services provided

Studies:
Design of rotating electrical machines and transformers
Electrical fault analysis
Tests and Trials:
Measurement of electrical machinery noise and vibration
Energy characterization of electric motors and transformers
Identification of electrical defects
Connector Test
Detection of partial discharge onset threshold (PDIV)
Breakdown tests

Training offers

Training: Noise and vibration/ Partial discharge measurements

Consulting services

We provide consulting services on all our skills

Equipments

Test platform of 500 m² dedicated to the tests of electric motors:
• Noise and vibration
• Energy efficiency
• Dielectric characterization
• Aging Campaign

Ecosystem

Affiliated institutions / organisations

Partner institution(s)

Groups/Networks/Federations

Doctoral schools

Regional strategic areas of activity

  • Energy and Environment
    • Energy efficiency and storage
    • Renewable energies
  • Transport and Mobility
    • Decarbonized vehicles, electromobility